You can customize the compression ratio of the LIM (limit) mode by changing the resistors R2 and R3. R2 sets the first ratio option on CON3 and R3 sets the second option.

  • For 4:1 ratio the resistor should be a jumper (stock option)
  • For 8:1 it should be 3.6k Ohms
  • For 12:1 it should be 9.1k Ohms (stock option)
  • For 20:1 it should be open (nothing mounted for the limit ratio resistor)